Requirements

Recent European legislation on EMC imposes limits on RF emissions from electrical equipment. These power line filters have been specifically developed for use with Yaskawa motor drives, enabling systems incorporating them to meet the European RFI emissions standards for domestic or industrial use.

 
Ranges Covered
Inverters
200V Single Phase
200V Three Phase
400V Three Phase
0.1 to 4.0kW - footprint type
0.1 to 7.5kW - footprint type
0.2 to 7.5kW - footprint type
0.1 to 1.5kW - footprint type
0.1 to 4.0kW - footprint type
0.2 to 4.0kW - footprint type
0.4 to 18.5kW - footprint type
22 to 45kW - block type
0.4 to 18.5kW - footprint type
22 to 90kW - block type
0.4 to 15.0kW - footprint type
18.5 to 300kW - block type
0.4 to 55.0kW - footprint type
75.0 to 110kW - book type
132 to 300kW - block type
Servo Drives
200V Single Phase
200V Three Phase
400V Three Phase
0.03 to 1.5W - footprint type
0.5 to 3.0kW - footprint type

 

Design and Test Criteria

Generally with motor drive systems, the emission levels are greatly affected by the length of the cable between the drive itself and the motor - longer cables will cause considerably higher emissions.
The inverter / filter combinations here have been designed and tested to achieve compliance to:-

EN 55022:1994, Class B for use in domestic / light industrial environments (Equivalent to the RF emissions tests of Power Drive Standard

EN 61800-3:1996 for drives with <25A input current) when fitted with up to 25m motor output cable and to:

EN 55011:1991 Group 1, Class A for use in industrial environments (Equivalent to the RF emissions tests of Power Drive Standard

EN 61800-3:1996 for drives with >25A input current) when fitted with up to 50m motor output cable.

Earth Leakage Measurements

In single phase applications the earth leakage current is present all of the time. For three phase applications under normal conditions with the three phases balanced, earth leakage currents are extremely small - the max values stated are worst possible values such as would occur momentarily during switch on or failure of one or two phases.

Use of Filters with 200V Three Phase Inverters

These filter ranges may also be used with 200V three phase inverters, but care should be taken in the filter selection. The equivalent 200V model of an inverter will require approximately twice the current of the 400V model. For example, the RS 3020-G5 filter is suitable for the CIMR-G5E22P2 drive, but not the CIMR-G5E23P7, even though the latter will fit. Running a filter on under-voltage is perfectly acceptable, but running at over-current for any extended period is not advisable.

Technical Information

For more technical data, a separate data sheet is available for each filter model. This gives detailed dimensions, circuit diagram and electrical ratings.

 
Please click here to download the Yaskawa product catalogue (in PDF format).
 
 
Yaskawa - J7 Filter
 
Yaskawa F7 400V Range
 
Yaskawa V7 Filter
 
Yaskawa G5 Filter
 
Sigma-II Filter