| Rasmi Products:Customer Specifics:Fuji Electric:FVR-C11S |
| |
| EFL-C11 Range |
| |
|
- The EFL-C11 range, especially for Fuji FVR-C11S Series inverters.
- Help to ensure EMC compliance of machinery and installations using C11S drives.
- Footprint filters mount between the inverter and the panel, saving valuable space inside wiring cabinets.
- All filters are designed and manufatured to UL requirements and are CE marked.
|
| |
|
Applied
FVR-C11S
Inverter |
Filter
Part No |
Rated
Current |
Max
Rated
Voltage |
Leakage
Current
Nom / Max |
External
L x W x H
(mm) |
Mount Dims
X x Y
(mm) |
Inverter
Fixing |
Price
(£) |
FVR-0.1C11S-7EN
FVR-0.2C11S-7EN |
EFL-02.C11-7 |
3A |
1ph, 250V |
3.5mA |
180x86x38 |
155x60 |
4XM4 |
|
FVR-0.4C11S-7EN
FVR-0.75C11S-7EN |
EFL-0.75C11-7 |
12A |
1ph, 250V |
3.5mA |
180x86x38 |
155x60 |
4xM4 |
|
FVR-1.5C11S-7EN |
EFL-1.5C11-7 |
20A |
1ph, 250V |
3.5mA |
190x117x46 |
165x89 |
4xM4 |
|
FVR-2.2C11S-7EN |
EFL-2.2C11-7 |
29A |
1ph, 250V |
3.5mA |
240x148x46 |
216x118 |
4xM4 |
|
|
| |
Earth Leakage Measurements
In single phase applications, the earth leakage current is present all of the time.
For three phase applications - under normal conditions, with the three phases balanced, earth leakage currents are extremely small - the max values stated are worst possible values such as would occur momentarily during switch on or failure of one or two phases.
Design and Test Criteria
Generally with motor drive systems, the emission levels are greatly affected by the length of the cable between the drive itself and the motor - longer cables will cause considerably higher emissions. The inverter / filter combinations here, have been designed and tested to achieve compliance to :-
EN 55022:1994, Class B for use in domestic / light industrial environments (Equivelant to the RF emissions tests of Power Drive Standard EN 61800-3:1996 for drives with <25A input current) when fitted with up to 25m motor output cable and to EN 55011:1991 Group 1, Class A for use in industrial environments (Equivelant to the RF emissions tests of Power Drive Standard EN 61800-3:1996 for drives with >25A input current) when fitted with up to 50m motor output cable. |
| |
| |