Click here to search our site.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Rasmi Products:Customer Specifics:Moeller:FP 300 and RF 300
 
FP 300 and RF 300 Range
 
  • The FP-300 and RF-300 ranges, especially for Moeller DF6 and DV6 Series inverters.
  • Help to ensure EMC compliance of machinery and installations using DF6 and DV6 drives.
  • Footprint filters mount between the inverter and the panel, saving valuable space inside wiring cabinets. Block filters mount beside the inverter.
  • All filters are designed and manufatured to UL requirements and are CE marked.
  • Ex stock. Delivery within 3 days.
 
Footprint Type Dimensions RF Block Type Dimensions

 
Applied
DF6
Inverter
Applied
DV6
Inverter
Filter Part No
Rated Current
Max Rated Voltage
Leakage Current
Nom / Max
External
L x W x H(mm)
Mount Dims
X x Y
Inverter Fixing
Price (£)
DV6 340 075
DV6 340 1K5
DV6 340 2K2
DV6 340 4K0
DV6 340 5K5
FP 3016-300
16A
3ph, 480V
0.5 / 40mA
305 x 152 x 45
290 x 110
4 x M5
DF6 340 11K
DF6340 15K
DV6 340 7K5
DV6 340 11K
FP 3040-300
40A
3ph, 480V
0.5 / 40mA
315 x 213 x 53
300 x 170
4 x M6
DF6 340 18K5
DF6 340 22K
DF6 340 30K
DV6 340 15K
DV6 340 18K5
DV6 340 22K
FP 3077-300
77A
3ph, 480V
0.5 / 42mA
459 x 253 x 60
444 x 210
4 x M6
0
DF6 340 37K
DV6 340 30K
RF 3092-300
92A
3ph, 480V
0.5 / 42mA
400 x 105 x 195
384 x 65
-
DF6 340 45K
DF6 340 55K
DV6 340 37K
DV6 340 45K
DV6 340 55K
RF 3150-300
150A
3ph, 480V
0.5 / 40mA
479 x 110 x 240
464 x 80
-
 
 
Design and Test Criteria
Generally with motor drive systems the emission levels are greatly affected by the length of the cable between the drive itself and the motor - longer cables will cause considerably higher emissions.
These inverter / filter combinations have been designed and tested to achieve compliance to :-
EN 55022:1994, Class B for use in domestic / light industrial environments (equivalent to the RF emissions tests of Power Drive Standard EN 61800-3:1996 for drives with <25A input current) when fitted with up to 25m motor output cable and to EN 55011:1991 Group 1, Class A for use in industrial environments (equivalent to the RF emissions tests of Power Drive Standard EN 61800-3:1996 for drives with >25A input current) when fitted with up to 50m motor output cable.
 
 
 
All items are Ex-Stock, delivery made within 3 days of receipt of order.
Quantity discount available.
 
 