Click here to search our site.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Rasmi Products:Standard Ranges:MHP High Performance Filters: RF 3xxxx-MHP Three Phase Filters
 
RF 3xxxx-MHP Three Phase Filters
 
Part Number
Rating
@ 40°C
Case Style
Max Cable Entry (mm2 Shrouded)
Leakage Current (mA) Nom/Max
Power Loss (W)
Wght (kg)
L (MH)
Cx
Cy
Rx
Ry
Price
(£)
RF 3010-MHP
10A@480Vac
P
6
0.5 / 14
10
1.5
7.4
1.4
0.2
0.47
10
 
RF 3016-MHP
16A@480Vac
Q
6
0.5 / 27
15
1.8
5.6
3.3
0.5
0.47
10
 
RF 3030-MHP
30A@480Vac
R
10
0.5 / 27
27
2.0
1.1
2.9
0.5
0.47
10
 
RF 3045-MHP
45A@480Vac
S
16
0.5 / 27
32
3.0
1.6
2.9
0.5
0.47
10
 
RF 3055-MHP
55A@480Vac
T
25
0.5 / 27
50
3.2
1.2
2.9
0.5
0.47
10
 
RF 3075-MHP
75A@480Vac
T
25
0.5 / 27
50
4.0
0.5
3.3
0.5
0.47
10
 
RF 3100-MHP
100A@480Vac
U
35
0.5 / 27
69
5.5
0.4
3.3
0.5
0.47
10
 
RF 3130-MHP
130A@480Vac
V
70
3.0 / 130
47
7.5
0.7
6.6
1.7
0.47
10
 
 
RF 3xxx - MHP Three Phase Filters (Part No's: RF 3180 - RF 3990)
 
Part Number
Rating
@ 40°C
Case Style
Max Cable Entry (mm2)
Leakage Current (mA) Nom/Max
Power Loss (W)
Wght (kg)
L (MH)
Cx
Cy
Rx
Ry
Price
(£)
RF 3180-MHP
180A@480Vac
V
120 Shroud
3.0/130
82
11
0.5
6.6
1.7
0.47
10
RF 3280-MHP
280A@480Vac
W
M12 Stud
3.0/130
60
45
0.06
6.6
1.7
0.47
10
RF 3400-MHP
400A@480Vac
W
M16 Stud
4.0/130
80
50
0.06
6.6
1.7
0.47
10
RF 3500-MHP
500A@480Vac
N
M16 Tag
4.0/190
100
70
0.13
6.6
2.4
0.47
10
RF 3600-MHP
600A@480Vac
N
M16 Tag
4.0/190
125
70
0.13
6.6
2.4
0.47
10
RF 3880-MHP
880A@480Vac
N
M16 Tag
4.0/190
210
72
0.13
6.6
2.4
0.47
10
RF 3990-MHP
1000A@480Vac
N
M16 Tag
4.0/190
300
72
0.13
6.6
2.4
0.47
10
Insulation test voltage: Phase to Earth = 3.0kV DC Phase to Neutral = 2.1kV DC
 
 
Case Dimensions
   
Case Style
L
W
H
X
Y
Z
Mount
A1
85
54
41
75
-
-
M4
A2
114
58
46
103
-
-
M4
A3
156
58
46
143
-
-
M4
A4
120
86
58
110
51
-
M5
B
170
80
56
160
46
-
M5
E
270
140
90
258
106
-
M6
P
255
50
126
240
25
80
M6
Q
305
55
142
290
30
100
M6
R
335
60
160
320
35
100
M6
S
329
70
185
314
45
120
M6
T
329
80
220
314
55
160
M6
U
379
90
220
364
65
160
M6
V
429
110
240
414
80
160
M6
W
565
300
160
420
275
-
M8
N
690
365
180
648
300
-
M8
   
 
 
Insertion Loss

As per CISPR 17:- 50/50 symmetrical 50/50 asymmetrica

 
Typical Circuit Schematic

 

Earth Leakage currents are given for:-
nominal : power to all three phases
maximum : power to one phase only.
Maximum: may occur only during switch-on, switch-off and supply fault conditions.
 
Rasmi Products:Standard Ranges:MHP High Performance Filters:RF 3xxxx-MHP Three Phase Filters

 


Original Layout & Artwork by