Click here to search our site.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Rasmi Products:Standard Ranges:Output Chokes
 
RS OC Output Chokes
 
 
 
 
Output Choke
Approx Motor kW
Centre Hole C
Width
W
Height
H
Depth
D
Mounting
Dims X,Y
Mounting
Holes Dia
Price
(£)
RS OC/1
2.2
21
85
46
22
70 -
5
RS OC/2
15
28.5
105
62
25
90 -
5
RS OC/3
45
50
150
110
50
125 x 30
5
RS OC/4
>45
58
200
170
65
180 x 45
6
 
 
Circuit Schematic
 

The RS OC/x output chokes can be used in conjunction with the filters to improve EMC performance. They are especially effective where radiated emissions from long drive to motor cables are a problem e.g. corruption of near by control or data cable signals or radio / television interference. The correct fitting of an RS OC/x into the motor cable can eliminate these problems.

The table above gives approximate motor kW ratings for the RS OC/x chokes but the selection is ultimately governed by the type and thickness of motor cable fitted i.e. the motor cable must fit through the OC centre hole.

Please click here to download the RS OC Series product catalogue (in PDF format).
 
Rasmi Products:Standard Ranges:Output Chokes

 


Original Layout & Artwork by