Click here to search our site.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Rasmi Products:Customer Specifics:Siemens:RF-MM4
 
RF-MM4 200-250V Single Phase Range
 
  • The MM4 range, especially for Siemens MicroMaster Series inverters.
  • Help to ensure EMC compliance of machinery and installations using MicroMaster 410, 420 and 440 Series single phase drives.
  • Footprint filters mount between the inverter and the panel, saving valuable space inside wiring cabinets.
  • All filters are designed and manufatured to UL requirements and are CE marked.
 

 

 

 

Applied
MM410
Inverter
6SE6410-2U
Applied
MM420
Inverter
6SEE6420-2U
Applied
MM440
Inverter
6SE6440-2U
Filter Part No
Rated
Current
Max Rated
Voltage
Leakage
Current
External
Dims
L x W x H
(mm)
Mount
Dims
X x Y
(mm)
Inverter
Fixing
Price
(£)
B11-2AA0
B12-5AA0
B13-7AA0
B15-5BA0
B17-5BA0
C11-2AA0
C12-5AA0
C13-7AA0
C15-5AA0
C17-5AA0
C11-2AA1
C12-5AA1
C13-7AA1
C15-5AA1
C17-5AA1
RF 1010-MM4
10A
1ph, 250V
3.5mA
200 x 73 x 40
187 x 56
2 x M4
C21-1BA0
C21-5BA0
C17-5BA0
C21-1BA1
C21-BBA1
C22-2BA1
RF1020-MM4
20A
1ph, 250V
3.5mA
213 x 149 x 40
200 x 120
4 x M4
C23-0CA0
C23-0CA1
RF 1030-MM4
30A
1ph, 250V
3.5mA
245 x 195 x 50
232 x 156
4 x M5
 
Earth Leakage Measurements
In single phase applications, the earth leakage current is present all of the time.
For three phase applications under normal conditions with the three phases balanced, earth leakage currents are extremely small - the max values stated are worst possible values such as would occur momentarily during switch on or failure of one or two phases.

Design and Test Criteria
Generally with motor drive systems the emission levels are greatly affected by the length of the cable between the drive itself and the motor - longer cables will cause considerably higher emissions.

These inverter / filter combinations have been designed and tested to achieve compliance to :-
EN 55022:1994, Class B for use in domestic / light industrial environments (equivalent to the RF emissions tests of Power Drive Standard EN 61800-3:1996 for drives with <25A input current) when fitted with up to 25m motor output cable and to EN 55011:1991 Group 1, Class A for use in industrial environments (equivalent to the RF emissions tests of Power Drive Standard EN 61800-3:1996 for drives with >25A input current) when fitted with up to 50m motor output cable.

 
Rasmi Products:Customer Specifics:Siemens:RF-MM4

 


Original Layout & Artwork by