Click here to search our site.  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Rasmi Products:Customer Specifics:Lenze:RF-LZ
 
RF-LZ Range
 

350-500V Three Phase

  • The LZ range, especially for Lenze8200 vector inverters.
  • Help to ensure EMC compliance of machinery and installations using 8200 vector
    invewrters on three phase supplies.
  • Footprint filters mount between the inverter and the panel, saving valuable space
    inside wiring cabinets.
  • All filters are designed and manufatured to UL requirements and are CE marked.
 
 
Dimensions
 
Applied
E82EV
Inverter
Filter Part No
Rated Current
Max Rated
Voltage
Leakage Current Nom / Max
External
L x W x H(mm)
Mount Dims
X x Y x M (mm)
Inverter Fixing
Price (£)
551K4C
751K4C
RF 3006-LZ2
6A
3ph, 500V
267 x 60 x 40
247 x 25 x M6
2 x M6
152K4C
222K4C
RF 3013-LZ3
13A
3ph, 500V
267 x 60 x 40
247 x 25 x M6
2 x M6
302K4C
402K4C
303K4C
RF 3017-LZ4
17A
3ph, 500V
337 x 100 x 60
317 x 12.5 x M6
2 x M6
752K4C
113K4C
RF 3021-LZ5
21A
3ph, 500V
337 x 125 x 60
317 x 25 x M6
2 x M6
153K4B
223K4B
303K4B
RF 3055-LZ6
55A
3ph, 500V
402 x 236 x 90
370 x 205 x M6
453K4B
RF 3080-LZ7
80A
3ph, 500V
580 x 318 x 90
532 x 284 x M10
553K4B
RF 3100-LZ8
100A
3ph, 500V
672 x 318 x 90
624 x 284 x M10
753K4B
RF 3165-LZ9
165A
3ph, 500V
750 x 428 x 90
702 x 395 x M10
 
Design and Test Criteria
Generally with motor drive systems the emission levels are greatly affected by the length of the cable between the drive itself and the motor - longer cables will cause considerably higher emissions.

These inverter / filter combinations have been designed and tested to achieve compliance to :-
EN 55022:1994, Class B for use in domestic / light industrial environments (equivalent to the RF emissions tests of Power Drive Standard EN 61800-3:1996 for drives with <25A input current) when fitted with up to 25m motor output cable and to EN 55011:1991 Group 1, Class A for use in industrial environments (equivalent to the RF emissions tests of Power Drive Standard EN 61800-3:1996 for drives with >25A input current) when fitted with up to 50m motor output cable.

 

  • Filter Installation Notes
    To conform to EMC directives, it is essential that good wiring practice is observed and that all installation recommendations are followed.
  • The usual safety procedures when working with electrical equipment must be followed and all electrical connections to the filter, inverter & motor must be made by a qualified electrical technician.
  • Filters should be fitted as closely as possible to the incoming mains supply of the wiring enclosure, usually directly after the enclosures circuit breaker or supply switch.Care should be taken to remove any paint etc. from filter and inverter mounting holes and face area of the panel to ensure the best possible earthing of the units.
  • All lead lengths should be kept as short as possible and incoming mains, outgoing motor cables and control cables should be kept well separated. Cable earth screens should
    only be stripped back as far as necessary to make connections - screens should be securely earth bonded to the wiring pan.
 
Typical Circuit Schematic

 

 
Rasmi Products:Customer Specifics:Lenze:RF-LZ

 


Original Layout & Artwork by